MIL-P-288B
TABLE I. Quality conformance inspection.
AQL
Percent defective
MIL-STD-105
Test method
major
Requirement
Examination and test
minor
Group A
3.3
3.4
Surface examination
4.5.1
3.5
1.5
4.0
4.5.1
3.6
1.5
4.0
4.5.1
1.5
4.0
3.7
Group B
Accuracy
3.5.1.1
4.5.2, 4.5.2.1,
.25
1.0
4.5.2.4
4.5.2, 4.5.2.2,
3.6.1.1
.25
1.0
4.5.2.4
3.7.1.1
4.5.2, 4.5.2.3,
.25
1.0
4.5.2.4
Group C
Storage temperature
3.1.3 and
MIL-E-16400
see 4.4.1.3
3.10
Humidity
3.1.3
MIL-E-16400
see 4.4.1.3
Salt fog
3.1.3
MIL-E-16400
see 4.4.1.3
Fungus
3.1.3
MIL-E-16400
see 4.4.1.3
Vibration
3.1.3
MIL-E-16400
see 4.4.1.3
4.5 Examination and test method.
4.5.1 Surface examination. Each protractor selected for test under 4.4.2
shall be visually and dimensionally examined to verify conformance with require-
ments of this specification. Defects for basis of acceptable quality level
are classified in table II.
13